Handheld And Portable Ultrasonic Flow Meter For Single Medium(A+E 80FB)The ultrasonic flowmeter is a handheld type with clamp-on sensor which offers a variety of optional features. It is a compact and robust instrument that comprises additional functions that can turn it into more than just a flow meter.This ultrasonic flowmeter is widely used to measure water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave. Pipe line sizes range from 15 to 3000mm (1/2" to 118").Features--Real time data transfer
--Intuitive flow meter menu
--Heat measurement function optional
--Data logger and SD card
--Light weight and low cost
--Easy installation and operation
--Measuring temperature from 0-160 C (32 to 320 F)--Nice appearanceSpecificationsTransmitter
Power requirements: Built-in 24V Ni-MH battery provides 12 hrs of continuous operation Charging: 220V AC 56/60 Hz
Inputs/Outputs: 4-20mA, RS232 / RS485, Heat Flow
Dispaly: 4 line characters display instantaneous and accumulative flow, velocity and signal statusUnits: User configuredAmbient conditions: -20 °C to +75 °C ( -4 to +167°F), 0 to 85% relative humiditySize: 220*120*92mm (8-2/3"*4-3/4"*3-1/2"), 600gFlow rate: 0-10m/s (0-33"ft/s)
Accuracy (at calibrated conditions): Flow: ± 1% reading, Heat: ± 2%Repeatability: 0.2%
Transducer |
Technical parameters |
Standard S1 |
Standard M1 |
Standard L1 |
S1H |
M1H |
HS bracket |
HM bracket |
Applicable pipe (mm) |
15~100 |
50~700 |
300~6000 |
15~100 |
50~700 |
15~100 |
50~700 |
Material |
Aluminum alloy |
PES (Polyether Sulfone) |
Working frequency |
1 MHZ |
Installation method |
V (N,W) |
V,Z
|
Z method |
V (N,W) |
V,Z |
V (N,W) |
V,Z
|
Calibration |
Pairing & Calibrating for the complete machine |
Magnetism |
Yes |
N/A |
Yes |
Applicable temperature |
-40~90 °C
|
-40ºC~160 °C |
Protection |
IP68 |
Media type |
Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can transmit ultrasonic wave |
Medium turbidity |
<20000ppm with low bubble content |
Applicable pipes |
Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastics, and lining is permitted. |
Pipe lining material |
Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc. |
Signal cable |
Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional. |
Heat Measurement FunctionThis ultrasonic flowmeter could be used as a heating meter when equipped with PT100 resistance. Details and Accessaries